IC system
1
  • IC system
2
views: 397

IC system

Rate:
0.0000/5

( 0 reviews )

Item NO.: V017098 MOQ: 0
Weight:    0kgs
Package Size:  
 Price:
$0.00
 Qty:
      $0.00
 Shipping:   Calculate Shipping Cost

Instrument Description:
Ion chromatography system (IC-2010) using a self-developed gel Tosoh suppression mode, is equipped with autosampler integrated high performance ion chromatography analysis system. Simple operating system and high-resolution column dedicated the perfect combination of high speed, high sensitivity and determination of anions and cations and easily. In addition, dedicated system control and data analysis with ion chromatography workstation, but also provides a very easy instrument control functionality and high reliability of measurement environment.

main feature:
High-speed continuous multi-sample handling
● achieve a measurement time of not more than 5 minutes for high-throughput analysis
   And a dedicated high-speed separation column together with supporting the use of anionic, cationic measurement can be completed within 5 minutes. Can greatly shorten the processing time of the sample.
● 150-250 samples with continuous multi-sample handling capabilities
   Equipped to accommodate standard sample stage 150 samples. By measuring sequence (schedule) setting can be 250 samples
   Continuous processing. Matching high-throughput analysis, continuous multi-sample treatment can be completed efficiently in a short time.
High Performance specifications
● time of 5 minutes was diluted with automatic dilution function
   By autosampler automatic dilution function can be carried out continuously contain a high concentration of ions diluted sample injection and the like.
● function having a gradient elution
   You can change the eluent gradient measurement and flow. For simultaneous analysis more difficult ion or column cleaning operations can be more effective
   Manner.
● IC workstation equipped with running water GLP support functions
    Equipped to support the excellent water quality inspection test by the software specification (tap GLP) standard workflow functionality. Setting group
    After the reference value and manage projects, when the measurement result exceeds the allowable range will alarm notification.
High sensitivity stability test
● automatic exchange gel suppression ways to ensure high sensitivity analysis
    Gel suppression mode to suppress the rotary valve and suppression glue together, can be suppressed by the effect of guaranteed stable, continuous from high sensitivity
    Dynamic Analysis.

 
No comment
Total 0 records, divided into1 pages. First Prev Next Last
View History
Business time
9:00-22:00
  • Email:support@rig123.com